Non-Combustibility Tester

Application
The EN ISO 1182 Non-combustibility test is one of the series of Euroclass test standards. This test specifies a procedure for determining whether or not a material will contribute directly to fire development and is relevant to classification of all building products (including floorings) into classes A1 and A2.
Performance characteristics
- Non-Combustibility Furnace measures incombustibility and combustibility of uniform building material and non-uniform building material of actual element.
- The evaluations (results) are rising temperature in the furnace, basic mass loss and ignition of specimen.
- Single Zone Furnace operable at up to 900 ℃ with the Kanthal Ribbon Heater.
- 750±5℃ temperature automatically control by PID and Power controller.
- Provided with stabilized voltage supply for more quick temperature stabilization.
- Equipped with 3 thermocouples, for temperature in furnace, specimen center, and specimen surface respectively.
- 360 degree rotatable and height adjustable thermocouple scanning device.
- Inner furnace thermocouple device to calibrate the temperature of furnace.
Technical Parameters
- Thermocouples: OMEGA brand
- Insulated thermocouple, wire diameter in 0.3mm, outer diameter in 1.5mm.
- Ribbon Heater: Kanthal brand made in Switzerland
- Furnace Temperature: 750°C
- Tube Dimensions: Inner diameter: 75 mm, height: 150 mm, wall thickness: 10mm.

Airflow stabilizer: 500mm in height, a truncated shaped cone, the top diameter is 75mm, and the bottom opening is 10mm in diameter.

Dimension of Specimen holder: φ1.5mm Steel wire made, inner diameter in 46mm, height in 57mm
The equipment consists of:
- oven
- fume hood
- stand;
- sample holder for solids (at least 2 pcs.);
- sample holder for bulk materials (at least 2 pcs.);
- sample insertion device;
- temperature control (maintenance) and measuring (recording) device;
- data capture and processing software.
All listed equipment meets the requirements of the standard LST EN ISO 1182: 2020
Standards
- BS: BS 476-4
- ISO: ISO 1182 2020
- EN: EN 13501
- IMO: FTPC Part 1
Size
- Furnace: 400 mm (W) x 400 mm (D) x 1200 mm (H)
- Control Unit: 530 mm (W) × 270 mm (D) × 280 mm (H)
Installation Requirements
- Electrical: 110V AC 60Hz / 230V AC 50Hz, 10A
- Ambient Temperature: Operating 10°C to 35°C
- Dimensions: 400 mm (W) x 400 mm (D) x 1200 mm (H)
- Control Unit: 530 mm (W) × 270 mm (D) × 280 mm (H)
Accessories
- Computer one set
- Software
- Thermocouples OMEGA brand
- Ribbon Heater Kanthal brand made in Switzerland
- Electric furnace wire